A-01 Floor plan
E-01 Electrical
Materials
Ensuite bathroom proposed electrical plan, sheet E-01
Electrical locations over the A-01 floor plan. Interior room size: 112 by 124.875 inches. Four recessed lights and two Nola task lights above the basin centres. M1 is one plain wall mirror, provisionally 60 inches wide by 32 inches high, centred over the vanity at y86.875 inches. Confirm its height and clearances from the task lights and GFCI outlets. BL1 is one concealed LED backlight behind M1 and shares ambient dimmer D4 with one niche LED, NL1. NL1 sits at the top of N1, 66 inches above the finished shower floor, and directs 3000K light downward. Its complete assembly requires wet-location approval and an accessible driver outside the shower. One exhaust fan, three GFCI receptacles, a five-control bank and a provisional towel-warmer supply. G1 serves the vanity, G2 serves the hair dryer, and G3 serves the heated seat. B1 identifies the handheld bidet beside the toilet. The single existing window remains on the toilet wall. Dashed lines indicate control groups, not cable routes. A Licensed Electrical Contractor must finalize the electrical design before work. One drawing unit equals one inch; print at 1:32.
112"
28"
56"
28"
124 7/8"
Bench
Floating*
Shower / 112" x 48"
Low curb
DL1
4" gap
HH1
Handheld
Shower 01
Fixed + HH1
HH2
Handheld
Shower 02
Fixed + HH2
Entry
Toilet
N1
B1
Vanity
Existing window
L1
L2
L3
L4
EF1
BL1
NL1
V1
V2
G1
G2
G3
J1
S
S
S
S
S
CB1
D1 / D2
D3 / D4
F1
Electrical symbols
L1-L4 Recessed LED / 4 total
L1-L2: wet-location listed for the shower.
V1-V2 Nola task lights / 2 total
BL1 Backlight / one plain mirror M1
NL1 Niche-top LED / 1 total / 3000K
66" above shower floor; light downward.
Complete wet-location assembly required.
EF1 Ceiling exhaust fan / duct outdoors
G1 Vanity GFCI / above counter
G2 Hair dryer GFCI / above counter
G3 Heated seat GFCI / confirm height
J1 Towel-warmer supply / provisional
M1: 60" x 32" prov. / Nola + GFCI fit TBD.
CB1 / Entry control bank
D1
L1 + L2
Shower dimmer
D2
L3 + L4
General dimmer
D3
V1 + V2
Vanity dimmer
D4
BL1 + NL1
Ambient dimmer
F1
EF1
Fan timer
Proposed centre locations
Device
X / from left
Y / from top
L1 / L2
28" / 84"
24"
L3 / L4
28" / 84"
84"
V1 / V2
112"
71 7/8" / 101 7/8"
BL1
112"
86 7/8"
NL1
56"
-1 1/2"
EF1
56"
60"
G1 / G2
112"
90" / 115"
G3
31"
124 7/8"
CB1
0"
92"
J1 *
79"
124 7/8"
0
1'
2'
Actual size / 100%
* Bench support and drain cover removal / cleaning access: confirm before work.
Dashed lines: control groups, not cable routes. NL1 driver: accessible outside shower.
Electrician: approve complete LED assembly, dimmer and protection. * J1: verify window clearance.
Ensuite bathroom
Proposed electrical / reflected ceiling plan
Sheet
E-01
Scale at letter size
3/8" = 1'-0" / 1:32
Date
05 Sep 2026
Preliminary / not for construction
Licensed Electrical Contractor review required